ModPro

Decontamination Units · 20′ unit

Dirty side. Shower. Clean side.

20-foot multi-stage decontamination units for abatement, hazmat and industrial sites. Dirty room, shower and clean room in sequence, with the water, heat and ventilation to run a full shift.

stages
3
stages
worker flow
1-way
worker flow
shower on site
Hot
shower on site

Sizes

One size, built around your site.

20′container

Exterior
20′ L × 8′ W × 8′6″ H
Capacity
3-stage layout

Dirty room → shower → clean room, each with its own door, so workers move one way through the unit.

  • Three sealed compartments
  • Hot shower with greywater capture
  • Heated and ventilated
  • Lockers and benches
Quote a 20′ unit

How it works

Three stages, one direction.

Workers enter contaminated and leave clean. Each room has its own door so nothing crosses back.

  1. 01

    Dirty room

    Remove contaminated PPE and clothing. Lockers, bench, disposal bags, hooks.

  2. 02

    Shower

    Hot shower with greywater capture. Seamless FRP walls and coved floor hose down.

  3. 03

    Clean room

    Dry off and dress in clean clothing. Separate exit so clean never meets dirty.

→ Enter contaminatedWorkers move one direction onlyExit clean →

What's included

Built for the job, not just the brochure.

  • 01

    Three-stage flow

    Separate dirty room, shower and clean room with doors between each so contamination moves one direction only.

  • 02

    Hot water on site

    On-demand water heater, fresh-water tank and a shower pan that drains to a greywater holding tank or filtration.

  • 03

    Washable surfaces

    Seamless FRP walls, coved vinyl floor and stainless fixtures that hose down at the end of a shift.

  • 04

    Heated and ventilated

    Wall heaters and exhaust fans sized for cold-weather work and continuous air changes.

  • 05

    Storage both sides

    Lockers, benches and hooks on the dirty side; clean clothing storage on the clean side.

  • 06

    Self-contained

    Single power hookup, exterior fill and pump-out ports. Tows onto a site and runs the same day.

Gallery

Recent builds

See the full gallery →
    20-foot decontamination unit exterior with separate entry doors at each end
    Mechanical room with fresh-water tanks, on-demand water heater, electrical panel and wall heater
    Change room with hand sink, baseboard heat and LED lighting
    Looking through the unit's interior doors, with coat hooks and the water heater
    Shower stage with curtain and shower base, seen from the adjoining room
    View through the stages toward the exit door

Where they go

Common uses

  • Asbestos and lead abatement
  • Mould remediation
  • Hazmat response
  • Mining and smelter sites
  • Industrial shutdowns and turnarounds
  • Environmental clean-up projects

Standard build

Shell
20′ new or one-trip ISO container
Layout
Dirty room, shower room, clean room with interior doors
Surfaces
FRP walls and ceiling, coved sheet-vinyl floor
Water
Fresh-water tank, on-demand heater, shower
Waste
Greywater holding tank with exterior pump-out
Climate
Wall heaters, exhaust fans in each compartment
Electrical
Single exterior hookup, LED lighting, GFCI receptacles

Popular options

  • + Greywater filtration system
  • + Two shower stations
  • + Negative-air / HEPA provisions
  • + Boot wash station
  • + Trailer or skid mount
  • + Larger tanks for remote sites

Every unit is drawn and quoted to your requirements. Specs above describe a typical build.

Free estimate

Request a quote

Tell us what you need and where it's going. We'll come back with a build spec, timeline and delivered price — no pressure, no obligation.

United States
(650) 482-8234
Shop
5784 Glenmore Road, Abbotsford, BC